Exact affine clock bounds from supplied rate and timestamp-error qualifications.
Times are already normalized to microseconds. A rational is an integer or
{numerator, nonzero_denominator}. Policy supplies positive a_min/a_max,
combined timestamp/model epsilon_us, explicit host/device generation,
host_now_us, max_probe_age_us, inclusive valid_device_us, and nonnegative
holdover_rate (extra host microseconds per device microsecond outside the
observed span). Zero holdover rate explicitly assumes no additional wander.
These bounds/validity assumptions must come from caller qualification; this
solver cannot establish them. Epsilon must already cover device timestamp
error in host units. Probes contain generation, h1, d2, d3, h4 with integer
timestamps. Foreign, malformed or stale input fails; only the newest 64
otherwise valid probes constrain the polygon. Retained inputs preserve provenance.
An anchor supplies generation, sample_index, device_us, period_min_us, period_max_us and error_us. Its error covers acquisition/quantization in device units; its period interval must hold over the requested samples. Stream/epoch ownership and hardware evidence are caller contracts, never inferred here.